We will make just about every hard work to be excellent and ideal, and accelerate our methods for standing during the rank of intercontinental top-grade and high-tech enterprises for 100% Original China Air to Water Air Source Heat Pump, Our merchandise are widely recognized and dependable by users and can meet continuously building economic and social needs.
We will make just about every hard work to be excellent and ideal, and accelerate our methods for standing during the rank of intercontinental top-grade and high-tech enterprises for Air Source Heatpump, China Heat Pump, In order to meet the increasing requirement of customers both home and aboard, we will keep carrying forward the enterprise spirit of “Quality, Creativity, Efficiency and Credit” and strive to top the current trend and lead fashion. We warmly welcome you to visit our company and make cooperation.
NULITE NEW ENERGY
Minus 25C 10KW 20KW High COP DC Inverter Split Air to Water Heat Pump.
1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW.
2.Best Selling Market: Central Europe North & East Europe, North Europe, North America.
3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output.
4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC.
5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Split Air Source Heat Pump.
HEAT PUMP TYPE | DC Inverter TypeSplit Heat Pump Air to Water Heating Cooling DC INVERTER 10-20KW |
MANUFACTURER | NULITE NEW ENERGY Group |
FACTORY SCALE | with in total 3 factory in China,400,000 sq meters. 500,000 units producing ability, 100,000 units sold in 2016 |
HEAT PUMP FUNCTION | Radiator, FCU, Floor Heating Cooling & Hot Water |
MOQ | 10-20 Units(1-2 Sample available with stocks) |
EFFICIENCY | COP 3.5-4.9 at Ambient 7C-25C |
SUITABLE MARKET | Minus 25C stable WorkingCentral, North & East Market, North America |
SUITABLE HEATING SPACE | TYPE OF HEAT PUMP USING AREA MODEL NAME DC Inverter Split Heat Pump 10KW (60-100m2) BKDX30-95DC Inverter Split Heat Pump 20KW (150-200m2) BKDX50-200 |
Item | BKDX30-95I/150S | BKDX50-200I/150S | BKDX50-200I/150S | |||||
Rated heating capicity | KW | 10 | 20 | 20 | ||||
Rated cooling capicity | KW | 2.7-6.6KW | 4.5-11KW | 4.5-11KW | ||||
Max input power | KW | 1-3KW | 2-5.5KW | 2.5-6.6KW | ||||
Rated current | A | 12 | 20 | 8 | ||||
Indoor unit Power supply | V/Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | ||||
Outdoor unit Power supply | V/Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | 380V 50Hz/60Hz | ||||
Rated output water temperature | °C | 45 | ||||||
Max output water temperature | °C | 60 | ||||||
Water flow | m³/h | 2.2 | 3.5 | 3.5 | ||||
Refrigeration | R410A | |||||||
Rated of waterproof | IPX4 | IPX4 | IPX4 | |||||
Prevent leakage protection | I class | I class | I class | |||||
Control mode | Microcomputer central processor (linear control) | |||||||
Compressor | Form | Scroll type | Scroll type | Scroll type | ||||
Quantity | 1 | 1 | 1 | |||||
Brand | Mitsubishi Twin Rotor DC Inverter | |||||||
Fan | Form | internal rotor motor,plastic leaves | ||||||
Fan power | W | 90 | 90*2 | 90*2 | ||||
Outdoor unit | Net size | mm | 910*445*977 | 979×418×1200 | 979×418×1200 | |||
Weight | Kg | 92 | 112 | 120 | ||||
Nosie level | dB(A) | ≤54 | ≤60 | ≤60 | ||||
Indoor unit | Auxilary heater | KW | 3 | 3 | 3 | |||
heat exchanger | stainless steel plate heat exchanger | |||||||
Net size | mm | 410*265*606 | 500*276*606 | 500*276*606 | ||||
Ambient temperature | °C | (-25℃ – 46℃) | (-25℃ – 46℃) | (-25℃ – 46℃) | ||||
Inlet pipe diameter | DN25 | DN25 | DN25 | |||||
Outlet pipe diameter | DN25 | DN25 | DN25 | |||||
Test Conditions Heating : Ambient temp.7°C/6°C,Water temp.40°C/45°C Cooling: DB / WB: 35°C/24°C Water Input:12°C ,Water Output:7°C |