Dependable good quality and very good credit score standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of “quality initial, shopper supreme” for 2019 China New Design China Energy-Saving Monoblock Type Water/Geothermal Source Heat Pump Ce, TUV Passed, We welcome you to inquire us by contact or mail and hope to construct an effective and cooperative romantic relationship.
Dependable good quality and very good credit score standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of “quality initial, shopper supreme” for China Heat Pump, Geothermal Source Heat Pump, With well educated, innovative and energetic staff, we’re responsible for all elements of research, design, manufacture, sale and distribution. By studying and developing new techniques, we’re not only following but also leading fashion industry. We listen attentively to the feedback from our customers and offer instant replies. You will instantly feel our expert and attentive service.
NULITE NEW ENERGY
Minus 25C 10KW 20KW High COP DC Inverter Split Air to Water Heat Pump.
1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW.
2.Best Selling Market: Central Europe North & East Europe, North Europe, North America.
3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output.
4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC.
5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Split Air Source Heat Pump.
HEAT PUMP TYPE | DC Inverter TypeSplit Heat Pump Air to Water Heating Cooling DC INVERTER 10-20KW |
MANUFACTURER | NULITE NEW ENERGY Group |
FACTORY SCALE | with in total 3 factory in China,400,000 sq meters. 500,000 units producing ability, 100,000 units sold in 2016 |
HEAT PUMP FUNCTION | Radiator, FCU, Floor Heating Cooling & Hot Water |
MOQ | 10-20 Units(1-2 Sample available with stocks) |
EFFICIENCY | COP 3.5-4.9 at Ambient 7C-25C |
SUITABLE MARKET | Minus 25C stable WorkingCentral, North & East Market, North America |
SUITABLE HEATING SPACE | TYPE OF HEAT PUMP USING AREA MODEL NAME DC Inverter Split Heat Pump 10KW (60-100m2) BKDX30-95DC Inverter Split Heat Pump 20KW (150-200m2) BKDX50-200 |
Item | BKDX30-95I/150S | BKDX50-200I/150S | BKDX50-200I/150S | |||||
Rated heating capicity | KW | 10 | 20 | 20 | ||||
Rated cooling capicity | KW | 2.7-6.6KW | 4.5-11KW | 4.5-11KW | ||||
Max input power | KW | 1-3KW | 2-5.5KW | 2.5-6.6KW | ||||
Rated current | A | 12 | 20 | 8 | ||||
Indoor unit Power supply | V/Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | ||||
Outdoor unit Power supply | V/Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | 380V 50Hz/60Hz | ||||
Rated output water temperature | °C | 45 | ||||||
Max output water temperature | °C | 60 | ||||||
Water flow | m³/h | 2.2 | 3.5 | 3.5 | ||||
Refrigeration | R410A | |||||||
Rated of waterproof | IPX4 | IPX4 | IPX4 | |||||
Prevent leakage protection | I class | I class | I class | |||||
Control mode | Microcomputer central processor (linear control) | |||||||
Compressor | Form | Scroll type | Scroll type | Scroll type | ||||
Quantity | 1 | 1 | 1 | |||||
Brand | Mitsubishi Twin Rotor DC Inverter | |||||||
Fan | Form | internal rotor motor,plastic leaves | ||||||
Fan power | W | 90 | 90*2 | 90*2 | ||||
Outdoor unit | Net size | mm | 910*445*977 | 979×418×1200 | 979×418×1200 | |||
Weight | Kg | 92 | 112 | 120 | ||||
Nosie level | dB(A) | ≤54 | ≤60 | ≤60 | ||||
Indoor unit | Auxilary heater | KW | 3 | 3 | 3 | |||
heat exchanger | stainless steel plate heat exchanger | |||||||
Net size | mm | 410*265*606 | 500*276*606 | 500*276*606 | ||||
Ambient temperature | °C | (-25℃ – 46℃) | (-25℃ – 46℃) | (-25℃ – 46℃) | ||||
Inlet pipe diameter | DN25 | DN25 | DN25 | |||||
Outlet pipe diameter | DN25 | DN25 | DN25 | |||||
Test Conditions Heating : Ambient temp.7°C/6°C,Water temp.40°C/45°C Cooling: DB / WB: 35°C/24°C Water Input:12°C ,Water Output:7°C |