We are also focusing on enhancing the things administration and QC program in order that we could keep fantastic advantage within the fiercely-competitive enterprise for 2019 China New Design Energy Saving DC Inverter Heat Pump Water Heater All in One Heat Pump, We have now a experienced crew for international trade. We are able to solve the problem you meet. We are able to offer the products and solutions you want. You should really feel free of charge to speak to us.
We are also focusing on enhancing the things administration and QC program in order that we could keep fantastic advantage within the fiercely-competitive enterprise for China Heat Pump and Air to Water Heat Pump, Our company always concentrate on the development of the international market. We have a lot of customers in Russia , European countries, the USA, the Middle East countries and Africa countries. We always follow that quality is foundation while service is guarantee to meet all customers.
ASHP Heating Capacity: DC Inverter Monoblock R32 WiFi control 10kw 15.5KW 20kw
1.Function:heating + cooling + hot water;
2.Voltage:220V/50Hz/1Phase or 380V/50Hz/3Phase;
3.Using R32 green refrigerant;
4.Super low noise with full DC fan motor;
5.Energy-saving is up to 80%;
6.Anti-freezing work in -25 degrees low temperature;
7.Adopted twin-rotor Panasonic or Mitsubishu compressor;
8.Build-in 3kW electric heater for back up;
9.WILO water pump RS15/6 or RS25/8;
10.AOL expansion tank 2L or 5L capacity;
11.Sweden SWEP plate heat exchanger;
12.Welcome to OEM,ODM service;
HEAT PUMP TYPE | DC Inverter TypeMonoblock Heat Pump Air to Water Heating Cooling DC INVERTER 10-30KW |
MANUFACTURER | Nulite NEW ENERGY Group |
FACTORY SCALE | with in total 3 factory in China,400,000 sq meters. 500,000 units producing ability, 100,000 units sold in 2016 |
HEAT PUMP FUNCTION | Radiator, FCU, Floor Heating Cooling & Hot Water |
MOQ | 10-20 Units(1-2 Sample available with stocks) |
EFFICIENCY | COP 3.5-4.9 at Ambient 7C-25C |
SUITABLE MARKET | Minus 25C stable WorkingCentral, North & East Market, North America |
SUITABLE HEATING SPACE | TYPE OF HEAT PUMP USING AREA MODEL NAMEDC Inverter Monoblock Heat Pump 10KW (60-100m2) BKDX30-95DC Inverter Monoblock Heat Pump 20KW (150-200m2) BKDX50-200 DC Inverter Monoblock Heat Pump 30KW (170-220m2) BKDX80-280(MOQ 20Units) |
Dc Inverter Heat Pump | NL- | BKDX30-95II/R32 | BKDX40-150II/R32 | BKDX50-200II/R32 | ||||
Rated heating capacity | KW | 2.8~10 | 3.8~16 | 5.5~21 | ||||
Rated hot water capacity | KW | 2.5~9.5 | 3.5~15.5 | 4.5~20 | ||||
Rated cooling capacity | KW | 2.5~7.5 | 3.8~11 | 4.8~14.5 | ||||
Heating power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | ||||
Hot water power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | ||||
Cooling power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | ||||
Voltage | V/Hz | 220V-240V – Inverter- 1N | 220V-240V – Inverter- 1N / 380V-415V ~ Inverter ~ 3N | |||||
Rated heating water temperature | °C | DHW: 55℃ / Heating:45℃ / Cooling:12℃ | ||||||
Rated water flow | m³/h | 1.7 | 2.7 | 3.5 | ||||
Refrigeration | / | R32 | R32 | R32 | ||||
Rated of waterproof | / | IPX4 | IPX4 | IPX4 | ||||
Control mode | / | Heating / Cooling / DHW / Heating+DHW/ Cooling+DHW | ||||||
Compressor | Form | / | Double-rotor type | Double-rotor type | Double-rotor type | |||
Quantity | / | 1 | 1 | 1 | ||||
Brand | / | Panasonic | Panasonic | Mitsubishi | ||||
Outdoor unit | Net size | mm | 1050*460*838 | 1050*460*1338 | 996×470×1385 | |||
Weight | Kg | 100 | 150 | 155 | ||||
Nosie level | dB(A) | ≤50 | ≤50 | ≤52 | ||||
Heat exchanger | / | Sweden SWEP Plate heat exchanger | ||||||
Fan | Form | Full DC fan motor | ||||||
Auxiliary Element | built-in | KW | 3 | 3 | 3 | |||
Circulation pump | built-in | Wilo | RS-15/6 | RS-25/8 | RS-25/8 | |||
Expansion tank | built-in | L | 2 | 5 | 5 | |||
Ambient temperature | °C | (-25℃ – 43℃) | (-25℃ – 43℃) | (-25℃ – 43℃) | ||||
Inlet pipe diameter | DN25 | DN25 | DN25 | |||||
Outlet pipe diameter | DN25 | DN25 | DN25 | |||||
Packing size | mm | 1110*520*968 | 1110*520*1488 | 1070*530*1530 | ||||
20″ container loading | pcs | 44 | 22 | 22 | ||||
40″ container loading | pcs | 88 | 44 | 44 |
Product Details Show
INSTALLING IN EU with more than 8,000 units NULITE heat pumps installed in EU market |
CONTROLLER SYSTEM Intelligent Control Panel, with multi-defrosting system protection, with five mode chooseable, heating, cooling, hot water,hot water then heating, hot water then cooling |
More than 500 units heat pump produced daily in NULITEworkshops |
Packing&Delivery
HEAT PUMP PACKAGE STEP 1 | HEAT PUMP PACKAGE STEP 2 | HEAT PUMP PACKAGE STEP 3 |
HEAT PUMP PACKAGE STEP 4 | HEAT PUMP PACKAGE STEP 5 | HEAT PUMP PACKAGE STEP 6 |
Our Company
FQA:
1.What is your advantages,comparing with other water heaters?
Avoiding electric water heater leakage, dry, high power consumption.
Avoiding the drawbacks of gas water heater,such as producing harmful gases,Fits and starts etc.
Energy efficient, safety and environmental protection, all-weather operation,easy to use.
2.What is the function of our inverter heat pump?
1)Domestic hot water all year round
2)Space heating in winter
3)Space cooling in summer
3.What is the supply conditions of our product?
Heating test conditions : Ambient temp.7°C/6°C,Water temp.40°C/45°C
Refrigeration test conditions :Ambient temp.35°C,Water temp.12°C/7°C
Hot water test conditions : Ambienttemp.7°C/6°C,Water temp.9°C/55°C
4.How many years’guarantee?
2 years
5.What is the package?
Strong wood box plus carton box
CONTACT US RIGHT NOW!