We support our customers with ideal premium quality products and solutions and superior level assistance. Becoming the specialist manufacturer in this sector, now we have received rich practical experience in producing and managing for 2019 Latest Design China New Energy a+++ R32/R410A ERP Air to Water DC Inverter Heat Pump, Teamwork is encouraged at all levels with regular campaigns. Our research team experiments on various developments from the industry for improvement during the products.
We support our customers with ideal premium quality products and solutions and superior level assistance. Becoming the specialist manufacturer in this sector, now we have received rich practical experience in producing and managing for Air To Water Heat Pump, China Heat Pump, Only for accomplishing the good-quality product to meet customer’s demand, all of our products have been strictly inspected before shipment. We always think about the question on the side of the customers, because you win, we win!
ASHP Heating Capacity: DC Inverter Monoblock 10kw 15.5KW 20kw 30kw .
1.Function:heating + cooling + hot water;
2.Voltage:220V/50Hz/1Phase or 380V/50Hz/3Phase;
3.Using r410a /R32 green refrigerant;
4.Super low noise with full DC fan motor;
5.Energy-saving is up to 80%;
6.Anti-freezing work in -25 degrees low temperature;
7.Adopted twin-rotor Panasonic or Mitsubishu compressor;
8.Build-in 3kW electric heater for back up;
9.WILO water pump RS15/6 or RS25/8;
10.AOL expansion tank 2L or 5L capacity;
11.Sweden SWEP plate heat exchanger;
12.Welcome to OEM,ODM service;
HEAT PUMP TYPE | DC Inverter TypeMonoblock Heat Pump Air to Water Heating Cooling DC INVERTER 10-30KW |
MANUFACTURER | Nulite NEW ENERGY Group |
FACTORY SCALE | with in total 3 factory in China,400,000 sq meters. 500,000 units producing ability, 100,000 units sold in 2016 |
HEAT PUMP FUNCTION | Radiator, FCU, Floor Heating Cooling & Hot Water |
MOQ | 10-20 Units(1-2 Sample available with stocks) |
EFFICIENCY | COP 3.5-4.9 at Ambient 7C-25C |
SUITABLE MARKET | Minus 25C stable WorkingCentral, North & East Market, North America |
SUITABLE HEATING SPACE | TYPE OF HEAT PUMP USING AREA MODEL NAMEDC Inverter Monoblock Heat Pump 10KW (60-100m2) BKDX30-95 A+DC Inverter Monoblock Heat Pump 20KW (150-200m2) BKDX50-200 A+ DC Inverter Monoblock Heat Pump 30KW (170-220m2) BKDX80-280 A+(MOQ 20Units) |
DC Inverter Heat Pump | NL-BKDX30-95II/R | NL-BKDX40-150II/R | NL-BKDX50-200II/R | NL-BKDX80-300II/R | ||||||
Rated heating capacity | KW | 2.8~10 | 3.8~15.5 | 4.5~20 | 7.2~30 | |||||
Rated hot water capacity | KW | 2.5~9.5 | 3.5~15 | 4.0~19.4 | 7.0~29.5 | |||||
Rated cooling capacity | KW | 2.5~7.5 | 3.8~10 | 4.5~14 | 7.0~20 | |||||
Heating power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | 3~9 | |||||
Hot water power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | 3~10 | |||||
Cooling power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | 3~11 | |||||
Voltage | V/Hz | 220V-240V – Inverter- 1N | 220V-240V – Inverter- 1N / 380V-415V ~ Inverter ~ 3N | |||||||
Rated heating water temperature | °C | Hot water: 55C / heating:45C / cooling:12C | ||||||||
Rated water flow | m³/h | 1.7 | 2.7 | 3.5 | 3.8 | |||||
Refrigeration | / | R410 | R410a | R410a | R410a | |||||
Rated of waterproof | / | IPX4 | IPX4 | IPX4 | IPX4 | |||||
Control mode | / | Heating,Cooling,DHW, Heating+DHW,Cooling+DHW | ||||||||
Compressor | Form | / | Double-rotor type | Double-rotor type | Double-rotor type | Double-rotor type | ||||
Quantity | / | 1 | 1 | 1 | 1 | |||||
Brand | / | Mitsubishi | Mitsubishi | Mitsubishi | Mitsubishi | |||||
Outdoor unit | Net size | mm | 996*470*1000 | 996*470*1000 | 996×470×1385 | 1210×535×1495 | ||||
Weight | Kg | 100 | 125 | 150 | 200 | |||||
Nosie level | dB(A) | ≤50 | ≤50 | ≤52 | ≤55 | |||||
Heat exchanger | / | Sweden SWEP Plate heat exchanger | ||||||||
Fan | Form | Full DC fan motor | ||||||||
Auxiliary Element | built-in | KW | 3 | 3 | 3 | 3 | ||||
Circulation pump | built-in | Wilo | RS-25/8 | RS-25/8 | RS-25/8 | / | ||||
Expansion tank | built-in | L | 2 | 2 | 5 | 5 | ||||
Ambient temperature | °C | (-25℃ – 43℃) | (-25℃ – 43℃) | (-25℃ – 43℃) | (-25℃ – 43℃) | |||||
Inlet pipe diameter | DN25 | DN25 | DN25 | DN40 | ||||||
Outlet pipe diameter | DN25 | DN25 | DN25 | DN40 | ||||||
Packing size | mm | 1070*530*1130 | 1070*530*1130 | 1070*530*1530 | 1320*630*1620 | |||||
20″ container loading | pcs | 44 | 44 | 22 | 22 | |||||
40″ container loading | pcs | 88 | 88 | 44 | 44 |
NL-BKDX30-95II/R & NL-BKDX40-150II/R
(Build-in wilo water pump,expansion tank, heater and SWEP plate heat exchanger.)
NL-BKDX50-200II/R & NL-BKDX60-220II/R(Build-in wilo water pump,expansion tank, heater and SWEP plate heat exchanger.)
INSTALLING IN EU with more than 8,000 units NULITE heat pumps installed in EU market |
CONTROLLER SYSTEM Intelligent Control Panel, with multi-defrosting system protection, with five mode chooseable, heating, cooling, hot water,hot water then heating, hot water then cooling |
More than 500 units heat pump produced daily in NULITEworkshops |
Packing&Delivery
HEAT PUMP PACKAGE STEP 1 | HEAT PUMP PACKAGE STEP 2 | HEAT PUMP PACKAGE STEP 3 |
HEAT PUMP PACKAGE STEP 4 | HEAT PUMP PACKAGE STEP 5 | HEAT PUMP PACKAGE STEP 6 |
FQA:
1.What is your advantages,comparing with other water heaters?
Avoiding electric water heater leakage, dry, high power consumption.
Avoiding the drawbacks of gas water heater,such as producing harmful gases,Fits and starts etc.
Energy efficient, safety and environmental protection, all-weather operation,easy to use.
2.What is the function of our inverter heat pump?
1)Domestic hot water all year round
2)Space heating in winter
3)Space cooling in summer
3.What is the supply conditions of our product?
Heating test conditions : Ambient temp.7°C/6°C,Water temp.40°C/45°C
Refrigeration test conditions :Ambient temp.35°C,Water temp.12°C/7°C
Hot water test conditions : Ambienttemp.7°C/6°C,Water temp.9°C/55°C
4.How many years’guarantee?
2 years
5.What is the package?
Strong wood box plus carton box
CONTACT US RIGHT NOW!