Our improvement depends around the sophisticated gear, outstanding talents and repeatedly strengthened technology forces for 2022 New Style China 20kw CE ERP A+++ Approved Amitime Carton Box and Wooden Pallet hot water heat pump Air Source, We’ve been now seeking forward to even better cooperation with overseas consumers dependant on mutual added benefits. For anyone who is interested in almost any of our products and solutions, be sure to experience totally free to contact us for more specifics.
Our improvement depends around the sophisticated gear, outstanding talents and repeatedly strengthened technology forces for Air to Water, China Heat Pump, We’ve been consistently broadening the market within Romania in addition to preparation punching in extra premium quality merchandise connected with printer on t shirt so that you can Romania. Most people firmly believe we’ve the whole capacity to provide you happy solutions.
ASHP Heating Capacity: DC Inverter Monoblock 10kw 15.5KW 20kw 30kw .
1.Function:heating + cooling + hot water;
2.Voltage:220V/50Hz/1Phase or 380V/50Hz/3Phase;
3.Using r410a /R32 green refrigerant;
4.Super low noise with full DC fan motor;
5.Energy-saving is up to 80%;
6.Anti-freezing work in -25 degrees low temperature;
7.Adopted twin-rotor Panasonic or Mitsubishu compressor;
8.Build-in 3kW electric heater for back up;
9.WILO water pump RS15/6 or RS25/8;
10.AOL expansion tank 2L or 5L capacity;
11.Sweden SWEP plate heat exchanger;
12.Welcome to OEM,ODM service;
HEAT PUMP TYPE | DC Inverter TypeMonoblock Heat Pump Air to Water Heating Cooling DC INVERTER 10-30KW |
MANUFACTURER | Nulite NEW ENERGY Group |
FACTORY SCALE | with in total 3 factory in China,400,000 sq meters. 500,000 units producing ability, 100,000 units sold in 2016 |
HEAT PUMP FUNCTION | Radiator, FCU, Floor Heating Cooling & Hot Water |
MOQ | 10-20 Units(1-2 Sample available with stocks) |
EFFICIENCY | COP 3.5-4.9 at Ambient 7C-25C |
SUITABLE MARKET | Minus 25C stable WorkingCentral, North & East Market, North America |
SUITABLE HEATING SPACE | TYPE OF HEAT PUMP USING AREA MODEL NAMEDC Inverter Monoblock Heat Pump 10KW (60-100m2) BKDX30-95 A+DC Inverter Monoblock Heat Pump 20KW (150-200m2) BKDX50-200 A+ DC Inverter Monoblock Heat Pump 30KW (170-220m2) BKDX80-280 A+(MOQ 20Units) |
DC Inverter Heat Pump | NL-BKDX30-95II/R | NL-BKDX40-150II/R | NL-BKDX50-200II/R | NL-BKDX80-300II/R | ||||||
Rated heating capacity | KW | 2.8~10 | 3.8~15.5 | 4.5~20 | 7.2~30 | |||||
Rated hot water capacity | KW | 2.5~9.5 | 3.5~15 | 4.0~19.4 | 7.0~29.5 | |||||
Rated cooling capacity | KW | 2.5~7.5 | 3.8~10 | 4.5~14 | 7.0~20 | |||||
Heating power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | 3~9 | |||||
Hot water power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | 3~10 | |||||
Cooling power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | 3~11 | |||||
Voltage | V/Hz | 220V-240V – Inverter- 1N | 220V-240V – Inverter- 1N / 380V-415V ~ Inverter ~ 3N | |||||||
Rated heating water temperature | °C | Hot water: 55C / heating:45C / cooling:12C | ||||||||
Rated water flow | m³/h | 1.7 | 2.7 | 3.5 | 3.8 | |||||
Refrigeration | / | R410 | R410a | R410a | R410a | |||||
Rated of waterproof | / | IPX4 | IPX4 | IPX4 | IPX4 | |||||
Control mode | / | Heating,Cooling,DHW, Heating+DHW,Cooling+DHW | ||||||||
Compressor | Form | / | Double-rotor type | Double-rotor type | Double-rotor type | Double-rotor type | ||||
Quantity | / | 1 | 1 | 1 | 1 | |||||
Brand | / | Mitsubishi | Mitsubishi | Mitsubishi | Mitsubishi | |||||
Outdoor unit | Net size | mm | 996*470*1000 | 996*470*1000 | 996×470×1385 | 1210×535×1495 | ||||
Weight | Kg | 100 | 125 | 150 | 200 | |||||
Nosie level | dB(A) | ≤50 | ≤50 | ≤52 | ≤55 | |||||
Heat exchanger | / | Sweden SWEP Plate heat exchanger | ||||||||
Fan | Form | Full DC fan motor | ||||||||
Auxiliary Element | built-in | KW | 3 | 3 | 3 | 3 | ||||
Circulation pump | built-in | Wilo | RS-25/8 | RS-25/8 | RS-25/8 | / | ||||
Expansion tank | built-in | L | 2 | 2 | 5 | 5 | ||||
Ambient temperature | °C | (-25℃ – 43℃) | (-25℃ – 43℃) | (-25℃ – 43℃) | (-25℃ – 43℃) | |||||
Inlet pipe diameter | DN25 | DN25 | DN25 | DN40 | ||||||
Outlet pipe diameter | DN25 | DN25 | DN25 | DN40 | ||||||
Packing size | mm | 1070*530*1130 | 1070*530*1130 | 1070*530*1530 | 1320*630*1620 | |||||
20″ container loading | pcs | 44 | 44 | 22 | 22 | |||||
40″ container loading | pcs | 88 | 88 | 44 | 44 |
NL-BKDX30-95II/R & NL-BKDX40-150II/R
(Build-in wilo water pump,expansion tank, heater and SWEP plate heat exchanger.)
NL-BKDX50-200II/R & NL-BKDX60-220II/R(Build-in wilo water pump,expansion tank, heater and SWEP plate heat exchanger.)
INSTALLING IN EU with more than 8,000 units NULITE heat pumps installed in EU market |
CONTROLLER SYSTEM Intelligent Control Panel, with multi-defrosting system protection, with five mode chooseable, heating, cooling, hot water,hot water then heating, hot water then cooling |
More than 500 units heat pump produced daily in NULITEworkshops |
Packing&Delivery
HEAT PUMP PACKAGE STEP 1 | HEAT PUMP PACKAGE STEP 2 | HEAT PUMP PACKAGE STEP 3 |
HEAT PUMP PACKAGE STEP 4 | HEAT PUMP PACKAGE STEP 5 | HEAT PUMP PACKAGE STEP 6 |
FQA:
1.What is your advantages,comparing with other water heaters?
Avoiding electric water heater leakage, dry, high power consumption.
Avoiding the drawbacks of gas water heater,such as producing harmful gases,Fits and starts etc.
Energy efficient, safety and environmental protection, all-weather operation,easy to use.
2.What is the function of our inverter heat pump?
1)Domestic hot water all year round
2)Space heating in winter
3)Space cooling in summer
3.What is the supply conditions of our product?
Heating test conditions : Ambient temp.7°C/6°C,Water temp.40°C/45°C
Refrigeration test conditions :Ambient temp.35°C,Water temp.12°C/7°C
Hot water test conditions : Ambienttemp.7°C/6°C,Water temp.9°C/55°C
4.How many years’guarantee?
2 years
5.What is the package?
Strong wood box plus carton box
CONTACT US RIGHT NOW!