Our company since its inception, always regards product quality as enterprise life, continuously improve production technology, improve product quality and continuously strengthen enterprise total quality management, in strict accordance with the national standard ISO 9001:2000 for Best Price for China Air Cooled Ducted Split Air Conditioner Heat Pump, The principle of our company is to provide high-quality products, professional service, and honest communication. Welcome all friends to place trial order for creating a long-term business relationship.
Our company since its inception, always regards product quality as enterprise life, continuously improve production technology, improve product quality and continuously strengthen enterprise total quality management, in strict accordance with the national standard ISO 9001:2000 for China Air Cooled Ducted Split Unit, Floor Standing Split Type Air Conditioner, We welcome customers from all over the world come to discuss business. We supply high quality products and solutions, reasonable prices and good services. We hope to sincerely build business relationships with customers from at home and abroad, jointly striving for a resplendent tomorrow.
NULITE NEW ENERGY
Minus 25C 10KW 20KW High COP DC Inverter Split Air to Water Heat Pump.
1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW.
2.Best Selling Market: Central Europe North & East Europe, North Europe, North America.
3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output.
4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC.
5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Split Air Source Heat Pump.
HEAT PUMP TYPE | DC Inverter TypeSplit Heat Pump Air to Water Heating Cooling DC INVERTER 10-20KW |
MANUFACTURER | NULITE NEW ENERGY Group |
FACTORY SCALE | with in total 3 factory in China,400,000 sq meters. 500,000 units producing ability, 100,000 units sold in 2016 |
HEAT PUMP FUNCTION | Radiator, FCU, Floor Heating Cooling & Hot Water |
MOQ | 10-20 Units(1-2 Sample available with stocks) |
EFFICIENCY | COP 3.5-4.9 at Ambient 7C-25C |
SUITABLE MARKET | Minus 25C stable WorkingCentral, North & East Market, North America |
SUITABLE HEATING SPACE | TYPE OF HEAT PUMP USING AREA MODEL NAME DC Inverter Split Heat Pump 10KW (60-100m2) BKDX30-95DC Inverter Split Heat Pump 20KW (150-200m2) BKDX50-200 |
Item | BKDX30-95I/150S | BKDX50-200I/150S | BKDX50-200I/150S | |||||
Rated heating capicity | KW | 10 | 20 | 20 | ||||
Rated cooling capicity | KW | 2.7-6.6KW | 4.5-11KW | 4.5-11KW | ||||
Max input power | KW | 1-3KW | 2-5.5KW | 2.5-6.6KW | ||||
Rated current | A | 12 | 20 | 8 | ||||
Indoor unit Power supply | V/Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | ||||
Outdoor unit Power supply | V/Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | 380V 50Hz/60Hz | ||||
Rated output water temperature | °C | 45 | ||||||
Max output water temperature | °C | 60 | ||||||
Water flow | m³/h | 2.2 | 3.5 | 3.5 | ||||
Refrigeration | R410A | |||||||
Rated of waterproof | IPX4 | IPX4 | IPX4 | |||||
Prevent leakage protection | I class | I class | I class | |||||
Control mode | Microcomputer central processor (linear control) | |||||||
Compressor | Form | Scroll type | Scroll type | Scroll type | ||||
Quantity | 1 | 1 | 1 | |||||
Brand | Mitsubishi Twin Rotor DC Inverter | |||||||
Fan | Form | internal rotor motor,plastic leaves | ||||||
Fan power | W | 90 | 90*2 | 90*2 | ||||
Outdoor unit | Net size | mm | 910*445*977 | 979×418×1200 | 979×418×1200 | |||
Weight | Kg | 92 | 112 | 120 | ||||
Nosie level | dB(A) | ≤54 | ≤60 | ≤60 | ||||
Indoor unit | Auxilary heater | KW | 3 | 3 | 3 | |||
heat exchanger | stainless steel plate heat exchanger | |||||||
Net size | mm | 410*265*606 | 500*276*606 | 500*276*606 | ||||
Ambient temperature | °C | (-25℃ – 46℃) | (-25℃ – 46℃) | (-25℃ – 46℃) | ||||
Inlet pipe diameter | DN25 | DN25 | DN25 | |||||
Outlet pipe diameter | DN25 | DN25 | DN25 | |||||
Test Conditions Heating : Ambient temp.7°C/6°C,Water temp.40°C/45°C Cooling: DB / WB: 35°C/24°C Water Input:12°C ,Water Output:7°C |