Home
Products
DC Inverter Heat Pump
Monoblock (EVI) Inverter Heat Pump
Split Inverter Heat Pump
All-In-One Heat Pump(Built-in tank)
Commercial Heat Pump
High-temp(℃)Heat Pump
On-off Water Heater Heat Pump
(EVI) Air Conditioning Heat Pump
Swimming Pool Heat Pump
Residential Pool Heater Heat Pump
Commercial Swim Pool Heat Pump
Geothermal/Water Source Heat Pump
Fan Coils
Pressurized Water Tanks
News
Production application
FAQs
About Us
Technology
About HP
Contact Us
English
Home
Tag Archives: Heat Pump For House Heating
Heat Pump For House Heating
PriceList for Cheap Heat Pumps - 9kw high temperature 80c heat pump NERS-B3S-I – New Energy
1.Compressor: Copelan*ZW series compressor with R134a refrigerant,Running Temp: -10℃~45℃ 2.Internal rotor motor, magnesium aluminum alloy leaves. 3.Reverse preventing frosting function of evaporator, hydrophilic fin. 4.Colored plate, with fashion appearance design. 5.Super performance in high COP, can work under the ambient temperature range from -10 to 43 degree. 6.Intelligent Microcomputer controller,Timer and Clock Function,Timer and Clock Function,Parameters Setting Permissions,L...
inquiry
detail
Hot-selling Solar Heat Pump - 35KW EVI heat pump for heating cooling model NERS-G10KD – New Energy
Product Information Specification Item NERS- B/3KD B/5KD G/10KD G/20KD Rated heating capicity KW 9.9 17.5 35 72 Rated cooling capicity KW 7.8 13.7 27.4 56 Rated input power KW 2.35 4.56 9.12 18.5 Max input power KW 3.29 6.5 13.1 27.2 Voltage (V) V/Hz 220v-1phase 380V-3phase Rated output cool water temp °C 8°C~12°C Rated output heating water temp °C 25°C~40°C Refrigeration R407C Control mode Microcomputer central processor (linear control) C...
inquiry
detail
OEM manufacturer Air Source Heatpump - Hot sale 40kw G10Y New Energy swimming pool heat pump for outdoor pool water heating – New Energy
Specification Model NERS- B/1.5Y B/2Y B/2.5Y B/3Y B/5Y B/6Y G/8Y G/10Y G/12Y G/24Y G/30Y G/40Y Rated heating capicity KW 6.5 9 10.5 12.8 22.5 26.2 34.5 45 53.2 101 120 150 Cooling capicity KW 4.55 6.3 7.35 8.96 15.7 18.3 23.5 30 37.2 74.2 91 106.8 Input power KW 1.2 1.67 1.95 2.43 4.24 5.12 6.65 8.65 10.2 19.6 23.5 29.1 Power source V/Hz 220V-240V 50Hz / 1phase 380V-400V / 50HZ / 3phase Rated output water temperature °C Rated temperature : 26℃~28℃ , Max temperature : 40℃ ...
inquiry
detail
Fixed Competitive Price Pompe A Chaleur - monoblock DC Inverter 10KW BKDX30-95I/1/S A+ Heat Pump Water Heater(Heating & Cooling & Hot Water) – New Energy
NEW ENERGY Minus 25C 10KW 20KW High COP DC Inverter Monoblock Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Heat Pump. HEAT PUMP TYPE DC I...
inquiry
detail
China Manufacturer for Heat Pump Inverter - 8KW-112KW geothermal heat pump for heating cooling DHW – New Energy
GS series Geothermal source heat pump(heating and cooling or hot water unit) Item NERS- G/2S G/3S G/4S G/5S G/6S G/8S G/10S G/12S G/16S G/20S G/25S G/30S G/40S G/50S Rated heating water capicity (W) W 7400 10800 14300 17700 21100 28100 34000 40800 54300 71300 89200 108700 137000 178000 Input power (W) W 1700 2500 3300 4100 4900 6400 7700 9500 9500 13200 13200 25900 32600 42400 COP 4.35 4.32 4.33 4.32 4.31 4.39 4.42 4.29 5.72 5.40 6.76 4.20 4.20 4.20 Rated cool...
inquiry
detail
Top Quality Heat Pump Price - 24kw commercial use hot water supply model NERS-G6B – New Energy
GB series commercial heat pump Model NERS- G/3B G/5B G/6B G/8B G/10B G/12B G/20B G/24B G/30B Rated heating capicity KW 11.4KW 19.7KW 23.57KW 30kw 38.5KW 44.7KW 72KW 90.3KW 112KW Input power KW 2.57KW 4.45KW 5.3KW 7.5KW 8.73KW 10.11KW 18KW 20.3KW 27.8KW Voltage V/Hz 380V-50Hz 380V-50Hz 380V/50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz Rated output water temperature °C Rated output water quantity (L) L 240 420 507 645 830 960 1504 1940 2430 ...
inquiry
detail
Personlized Products R410a Heat Pump - 8KW-112KW geothermal heat pump for heating cooling DHW – New Energy
GS series Geothermal source heat pump(heating and cooling or hot water unit) Item NERS- G/2S G/3S G/4S G/5S G/6S G/8S G/10S G/12S G/16S G/20S G/25S G/30S G/40S G/50S Rated heating water capicity (W) W 7400 10800 14300 17700 21100 28100 34000 40800 54300 71300 89200 108700 137000 178000 Input power (W) W 1700 2500 3300 4100 4900 6400 7700 9500 9500 13200 13200 25900 32600 42400 COP 4.35 4.32 4.33 4.32 4.31 4.39 4.42 4.29 5.72 5.40 6.76 4.20 4.20 4.20 Rated cool...
inquiry
detail
Factory Promotional 60hz Heat Pump - 8KW-112KW geothermal heat pump for heating cooling DHW – New Energy
GS series Geothermal source heat pump(heating and cooling or hot water unit) Item NERS- G/2S G/3S G/4S G/5S G/6S G/8S G/10S G/12S G/16S G/20S G/25S G/30S G/40S G/50S Rated heating water capicity (W) W 7400 10800 14300 17700 21100 28100 34000 40800 54300 71300 89200 108700 137000 178000 Input power (W) W 1700 2500 3300 4100 4900 6400 7700 9500 9500 13200 13200 25900 32600 42400 COP 4.35 4.32 4.33 4.32 4.31 4.39 4.42 4.29 5.72 5.40 6.76 4.20 4.20 4.20 Rated cool...
inquiry
detail
Cheapest Price Cheap Heat Pumps - DC Inverter All In One 38KW NE-NC10BZ-B2FIIF Heat Pump Water Heater(Heating & Cooling) – New Energy
NEW ENERGY Minus 25C 10KW 20KW 22KW 30KW 38KW High COP DC Inverter All In One Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter All In One 10KW 20KW 22KW 30KW 38KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Hea...
inquiry
detail
New Fashion Design for Solar Heat Pump Water Heater - DC Inverter All In One 30KW NE-C8BZ-B2FIIF Heat Pump Water Heater(Heating & Cooling) – New Energy
NEW ENERGY Minus 25C 10KW 20KW 22KW 30KW 38KW High COP DC Inverter All In One Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter All In One 10KW 20KW 22KW 30KW 38KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Hea...
inquiry
detail
OEM Factory for Apartment Heat Pump - Air source water heater domestic heat pump pool water heat exchanger 20kw B5Y – New Energy
Specification Model NERS- B/1.5Y B/2Y B/2.5Y B/3Y B/5Y B/6Y G/8Y G/10Y G/12Y G/24Y G/30Y G/40Y Rated heating capicity KW 6.5 9 10.5 12.8 22.5 26.2 34.5 45 53.2 101 120 150 Cooling capicity KW 4.55 6.3 7.35 8.96 15.7 18.3 23.5 30 37.2 74.2 91 106.8 Input power KW 1.2 1.67 1.95 2.43 4.24 5.12 6.65 8.65 10.2 19.6 23.5 29.1 Power source V/Hz 220V-240V 50Hz / 1phase 380V-400V / 50HZ / 3phase Rated output water temperature °C Rated temperature : 26℃~28℃ , Max temperature : 40℃ Wat...
inquiry
detail
factory customized Air Source Heatpump - NERS-G24Q 82KW Heating Cooling DHW 3 in 1 air to water heat pump – New Energy
Specification Item NERS- G/5Q G/10Q G/12Q G/15Q G/24Q G/30Q G/40Q G/50Q G/60Q G/80Q Rated heating capicity (W) W 16340 35420 41040 48100 82080 96000 135000 173000 215000 283000 Rated cooling capicity (W) W 12500 26720 31480 36200 63990 73000 92000 115000 145000 196000 Input power for heating (W) W 4800 9560 11200 12800 22410 26900 33800 43900 55200 71400 Input power for cooling (W) W 4300 9320 10800 12300 21600 26000 33000 43000 54000 70000 Voltage (V) V/Hz 3...
inquiry
detail
<<
< Previous
5
6
7
8
9
10
11
Next >
>>
Page 8 / 13
Phone
Tel
+86 20 86833226
E-mail
E-mail
nulite01@ne01-e.com
Hit enter to search or ESC to close