Being supported by an highly developed and specialist IT team, we could provide technical support on pre-sales & after-sales assistance for OEM/ODM Factory China 5-24kw R32 DC Inverter Heat Pump, We welcome shoppers, business enterprise associations and close friends from all sections with the globe to contact us and seek cooperation for mutual added benefits.
Being supported by an highly developed and specialist IT team, we could provide technical support on pre-sales & after-sales assistance for China Swimming Pool Heat Pump, Heat Pump, Till now, the items list has been updated regularly and attracted clients from around the globe. Comprehensive facts is often obtained in our web-site and you’ll be served with premium quality consultant service by our after-sale group. They are likely to help you get thorough acknowledge about our goods and make a satisfied negotiation. Company go to to our factory in Brazil is also welcome at any time. Hope to obtain your inquiries for any pleased co-operation.
ASHP Heating Capacity: DC Inverter Monoblock 10kw 15.5KW 20kw 30kw .
1.Function:heating + cooling + hot water;
2.Voltage:220V/50Hz/1Phase or 380V/50Hz/3Phase;
3.Using r410a /R32 green refrigerant;
4.Super low noise with full DC fan motor;
5.Energy-saving is up to 80%;
6.Anti-freezing work in -25 degrees low temperature;
7.Adopted twin-rotor Panasonic or Mitsubishu compressor;
8.Build-in 3kW electric heater for back up;
9.WILO water pump RS15/6 or RS25/8;
10.AOL expansion tank 2L or 5L capacity;
11.Sweden SWEP plate heat exchanger;
12.Welcome to OEM,ODM service;
HEAT PUMP TYPE | DC Inverter TypeMonoblock Heat Pump Air to Water Heating Cooling DC INVERTER 10-30KW |
MANUFACTURER | Nulite NEW ENERGY Group |
FACTORY SCALE | with in total 3 factory in China,400,000 sq meters. 500,000 units producing ability, 100,000 units sold in 2016 |
HEAT PUMP FUNCTION | Radiator, FCU, Floor Heating Cooling & Hot Water |
MOQ | 10-20 Units(1-2 Sample available with stocks) |
EFFICIENCY | COP 3.5-4.9 at Ambient 7C-25C |
SUITABLE MARKET | Minus 25C stable WorkingCentral, North & East Market, North America |
SUITABLE HEATING SPACE | TYPE OF HEAT PUMP USING AREA MODEL NAMEDC Inverter Monoblock Heat Pump 10KW (60-100m2) BKDX30-95 A+DC Inverter Monoblock Heat Pump 20KW (150-200m2) BKDX50-200 A+ DC Inverter Monoblock Heat Pump 30KW (170-220m2) BKDX80-280 A+(MOQ 20Units) |
DC Inverter Heat Pump | NL-BKDX30-95II/R | NL-BKDX40-150II/R | NL-BKDX50-200II/R | NL-BKDX80-280II/R | ||||||
Rated heating capacity | KW | 2.8~10 | 3.8~15.5 | 4.5~20 | 7.2~30 | |||||
Rated hot water capacity | KW | 2.5~9.5 | 3.5~15 | 4.0~19.4 | 7.0~29.5 | |||||
Rated cooling capacity | KW | 2.5~7.5 | 3.8~10 | 4.5~14 | 7.0~20 | |||||
Heating power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | 3~9 | |||||
Hot water power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | 3~10 | |||||
Cooling power consumption | KW | 1~3 | 1.5~4.5 | 2~5.5 | 3~11 | |||||
Voltage | V/Hz | 220V-240V – Inverter- 1N | 220V-240V – Inverter- 1N / 380V-415V ~ Inverter ~ 3N | |||||||
Rated heating water temperature | °C | Hot water: 55C / heating:45C / cooling:12C | ||||||||
Rated water flow | m³/h | 1.7 | 2.7 | 3.5 | 3.8 | |||||
Refrigeration | / | R410 | R410a | R410a | R410a | |||||
Rated of waterproof | / | IPX4 | IPX4 | IPX4 | IPX4 | |||||
Control mode | / | Heating,Cooling,DHW, Heating+DHW,Cooling+DHW | ||||||||
Compressor | Form | / | Double-rotor type | Double-rotor type | Double-rotor type | Double-rotor type | ||||
Quantity | / | 1 | 1 | 1 | 1 | |||||
Brand | / | Mitsubishi | Mitsubishi | Mitsubishi | Mitsubishi | |||||
Outdoor unit | Net size | mm | 996*470*1000 | 996*470*1000 | 996×470×1385 | 1210×535×1495 | ||||
Weight | Kg | 100 | 125 | 150 | 200 | |||||
Nosie level | dB(A) | ≤50 | ≤50 | ≤52 | ≤55 | |||||
Heat exchanger | / | Sweden SWEP Plate heat exchanger | ||||||||
Fan | Form | Full DC fan motor | ||||||||
Auxiliary Element | built-in | KW | 3 | 3 | 3 | 3 | ||||
Circulation pump | built-in | Wilo | RS-25/8 | RS-25/8 | RS-25/8 | / | ||||
Expansion tank | built-in | L | 2 | 2 | 5 | 5 | ||||
Ambient temperature | °C | (-25℃ – 43℃) | (-25℃ – 43℃) | (-25℃ – 43℃) | (-25℃ – 43℃) | |||||
Inlet pipe diameter | DN25 | DN25 | DN25 | DN40 | ||||||
Outlet pipe diameter | DN25 | DN25 | DN25 | DN40 | ||||||
Packing size | mm | 1070*530*1130 | 1070*530*1130 | 1070*530*1530 | 1320*630*1620 | |||||
20″ container loading | pcs | 44 | 44 | 22 | 22 | |||||
40″ container loading | pcs | 88 | 88 | 44 | 44 |
INSTALLING IN EU with more than 8,000 units NULITE heat pumps installed in EU market |
CONTROLLER SYSTEM Intelligent Control Panel, with multi-defrosting system protection, with five mode chooseable, heating, cooling, hot water,hot water then heating, hot water then cooling |
More than 500 units heat pump produced daily in NULITEworkshops |
HEAT PUMP PACKAGE STEP 1 | HEAT PUMP PACKAGE STEP 2 | HEAT PUMP PACKAGE STEP 3 |
HEAT PUMP PACKAGE STEP 4 | HEAT PUMP PACKAGE STEP 5 | HEAT PUMP PACKAGE STEP 6 |
FQA:
1.What is your advantages,comparing with other water heaters?
Avoiding electric water heater leakage, dry, high power consumption.
Avoiding the drawbacks of gas water heater,such as producing harmful gases,Fits and starts etc.
Energy efficient, safety and environmental protection, all-weather operation,easy to use.
2.What is the function of our inverter heat pump?
1)Domestic hot water all year round
2)Space heating in winter
3)Space cooling in summer
3.What is the supply conditions of our product?
Heating test conditions : Ambient temp.7°C/6°C,Water temp.40°C/45°C
Refrigeration test conditions :Ambient temp.35°C,Water temp.12°C/7°C
Hot water test conditions : Ambienttemp.7°C/6°C,Water temp.9°C/55°C
4.How many years’guarantee?
2 years
5.What is the package?
Strong wood box plus carton box
CONTACT US RIGHT NOW!
For the most suitable Heating Cooling, Hot Water Solution!