We thinks what customers think, the urgency of urgency to act during the interests of a purchaser position of theory, allowing for much better good quality, lower processing costs, prices are extra reasonable, won the new and old buyers the support and affirmation for Wholesale OEM China DC Inverter Heat Pump Air to Water Heating ERP a+++ 15kw 20kw, Our support concept is honesty, aggressive, realistic and innovation. With the assistance, we will improve much better.
We thinks what customers think, the urgency of urgency to act during the interests of a purchaser position of theory, allowing for much better good quality, lower processing costs, prices are extra reasonable, won the new and old buyers the support and affirmation for China Heat Pump, Dc Inverter Heat Pump, We integrate all our advantages to continuously innovate, improve and optimize our industrial structure and product performance. We are going to always believe in and work on it. Welcome to join us to promote green light, together we’ll make a better Future!
NULITE NEW ENERGY
Minus 25C 10KW 20KW High COP DC Inverter Split Air to Water Heat Pump.
1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW.
2.Best Selling Market: Central Europe North & East Europe, North Europe, North America.
3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output.
4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC.
5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Split Air Source Heat Pump.
HEAT PUMP TYPE | DC Inverter TypeSplit Heat Pump Air to Water Heating Cooling DC INVERTER 10-20KW |
MANUFACTURER | NULITE NEW ENERGY Group |
FACTORY SCALE | with in total 3 factory in China,400,000 sq meters. 500,000 units producing ability, 100,000 units sold in 2016 |
HEAT PUMP FUNCTION | Radiator, FCU, Floor Heating Cooling & Hot Water |
MOQ | 10-20 Units(1-2 Sample available with stocks) |
EFFICIENCY | COP 3.5-4.9 at Ambient 7C-25C |
SUITABLE MARKET | Minus 25C stable WorkingCentral, North & East Market, North America |
SUITABLE HEATING SPACE | TYPE OF HEAT PUMP USING AREA MODEL NAME DC Inverter Split Heat Pump 10KW (60-100m2) BKDX30-95DC Inverter Split Heat Pump 20KW (150-200m2) BKDX50-200 |
Item | BKDX30-95I/150S | BKDX50-200I/150S | BKDX50-200I/150S | |||||
Rated heating capicity | KW | 10 | 20 | 20 | ||||
Rated cooling capicity | KW | 2.7-6.6KW | 4.5-11KW | 4.5-11KW | ||||
Max input power | KW | 1-3KW | 2-5.5KW | 2.5-6.6KW | ||||
Rated current | A | 12 | 20 | 8 | ||||
Indoor unit Power supply | V/Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | ||||
Outdoor unit Power supply | V/Hz | 220V 50Hz/60Hz | 220V 50Hz/60Hz | 380V 50Hz/60Hz | ||||
Rated output water temperature | °C | 45 | ||||||
Max output water temperature | °C | 60 | ||||||
Water flow | m³/h | 2.2 | 3.5 | 3.5 | ||||
Refrigeration | R410A | |||||||
Rated of waterproof | IPX4 | IPX4 | IPX4 | |||||
Prevent leakage protection | I class | I class | I class | |||||
Control mode | Microcomputer central processor (linear control) | |||||||
Compressor | Form | Scroll type | Scroll type | Scroll type | ||||
Quantity | 1 | 1 | 1 | |||||
Brand | Mitsubishi Twin Rotor DC Inverter | |||||||
Fan | Form | internal rotor motor,plastic leaves | ||||||
Fan power | W | 90 | 90*2 | 90*2 | ||||
Outdoor unit | Net size | mm | 910*445*977 | 979×418×1200 | 979×418×1200 | |||
Weight | Kg | 92 | 112 | 120 | ||||
Nosie level | dB(A) | ≤54 | ≤60 | ≤60 | ||||
Indoor unit | Auxilary heater | KW | 3 | 3 | 3 | |||
heat exchanger | stainless steel plate heat exchanger | |||||||
Net size | mm | 410*265*606 | 500*276*606 | 500*276*606 | ||||
Ambient temperature | °C | (-25℃ – 46℃) | (-25℃ – 46℃) | (-25℃ – 46℃) | ||||
Inlet pipe diameter | DN25 | DN25 | DN25 | |||||
Outlet pipe diameter | DN25 | DN25 | DN25 | |||||
Test Conditions Heating : Ambient temp.7°C/6°C,Water temp.40°C/45°C Cooling: DB / WB: 35°C/24°C Water Input:12°C ,Water Output:7°C |