Home
Products
DC Inverter Heat Pump
Monoblock (EVI) Inverter Heat Pump
Split Inverter Heat Pump
All-In-One Heat Pump(Built-in tank)
Commercial Heat Pump
High-temp(℃)Heat Pump
On-off Water Heater Heat Pump
(EVI) Air Conditioning Heat Pump
Swimming Pool Heat Pump
Residential Pool Heater Heat Pump
Commercial Swim Pool Heat Pump
Geothermal/Water Source Heat Pump
Fan Coils
Pressurized Water Tanks
News
Production application
FAQs
About Us
Technology
About HP
Contact Us
English
Home
Tag Archives: R407c Heat Pump
R407c Heat Pump
Hot-selling Bathing Hot Water Sanitary Heat Pump - 4.2KW Heating Capacity New Energy Freestanding Fan Coil Unit NERS-FP51G – New Energy
Model NERS-FP51G Heating capacity W 4200 Cooling capacity W 3600 House heating area ㎡ 20-40 Power (W) W 30 Voltage (V) V 220V~50Hz Current A 0.09 Water flow L/S 0.08 Nosie level dB(A) 40 Max allowable pressure of heat exchanger MPa 1.6 Weight KG 22 Floor heating floorstanding digital fan coil (Ultra thin) NEW ENERGY customized floor fan coil Thinner ,more save space Product Spec Principle of working Strict quality control Successful projects &...
inquiry
detail
Super Lowest Price Mini Heat Pump - -25c work 10.4kw mono block EVI Air Source Heat Pump water heater model B3S-D – New Energy
GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Microcomputer central pr...
inquiry
detail
Professional Design Australia Heat Pump - High quality 120kw G30Y energy-saved new swim pool heat pump – New Energy
Specification Model NERS- B/1.5Y B/2Y B/2.5Y B/3Y B/5Y B/6Y G/8Y G/10Y G/12Y G/24Y G/30Y G/40Y Rated heating capicity KW 6.5 9 10.5 12.8 22.5 26.2 34.5 45 53.2 101 120 150 Cooling capicity KW 4.55 6.3 7.35 8.96 15.7 18.3 23.5 30 37.2 74.2 91 106.8 Input power KW 1.2 1.67 1.95 2.43 4.24 5.12 6.65 8.65 10.2 19.6 23.5 29.1 Power source V/Hz 220V-240V 50Hz / 1phase 380V-400V / 50HZ / 3phase Rated output water temperature °C Rated temperature : 26℃~28℃ , Max temperature : 40℃ ...
inquiry
detail
2019 High quality Defrosting Heat Pump - NERS-G5Q 16KW Heating Cooling DHW 3 in 1 air to water heat pump – New Energy
Specification Item NERS- G/5Q G/10Q G/12Q G/15Q G/24Q G/30Q G/40Q G/50Q G/60Q G/80Q Rated heating capicity (W) W 16340 35420 41040 48100 82080 96000 135000 173000 215000 283000 Rated cooling capicity (W) W 12500 26720 31480 36200 63990 73000 92000 115000 145000 196000 Input power for heating (W) W 4800 9560 11200 12800 22410 26900 33800 43900 55200 71400 Input power for cooling (W) W 4300 9320 10800 12300 21600 26000 33000 43000 54000 70000 Voltage (V) V/Hz 3...
inquiry
detail
China OEM Quite Heat Pump - 5.1KW 70degre household water heater floorstanding 220L all in one heat pump – New Energy
Specification Item NERS- NE-K115/L200 NERS-FR200 Rated heating capicity W 5390 5390 Input power W 1275 1275 Voltage V/Hz 220V-50Hz Rated output water temperature °C 55°C Max output water temperature °C 70°C Continuous output water quantity L 200L 240L Refrigerant R134a Control mode Microcomputer central processor (touch control) Compressor form Rotation type quantity 1 brand Mitsubishi Net size mm 430*460*1400 450*487*1415 Net weight kg 85 90 Noise dB(A) &l...
inquiry
detail
OEM/ODM China Air Source Evi Heat Pump - -25c work 38.5kw mono block EVI Air Source Heat Pump water heater model NERS-G10D – New Energy
GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Microcomputer central pr...
inquiry
detail
Top Suppliers House Heat Pump - DC Inverter All In One 10KW NE-C3BZ-B2F Heat Pump Water Heater(Heating & Cooling) – New Energy
NEW ENERGY Minus 25C 10KW 20KW 22KW 30KW 38KW High COP DC Inverter All In One Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter All In One 10KW 20KW 22KW 30KW 38KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Hea...
inquiry
detail
2019 New Style Tepelne Cerpadlo - -25c work 19.7kw mono block EVI Air Source Heat Pump water heater model B5S-D – New Energy
GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Microcomputer central pr...
inquiry
detail
High Quality Monobloc Heat Pump - NERS-G24Q 82KW Heating Cooling DHW 3 in 1 air to water heat pump – New Energy
Specification Item NERS- G/5Q G/10Q G/12Q G/15Q G/24Q G/30Q G/40Q G/50Q G/60Q G/80Q Rated heating capicity (W) W 16340 35420 41040 48100 82080 96000 135000 173000 215000 283000 Rated cooling capicity (W) W 12500 26720 31480 36200 63990 73000 92000 115000 145000 196000 Input power for heating (W) W 4800 9560 11200 12800 22410 26900 33800 43900 55200 71400 Input power for cooling (W) W 4300 9320 10800 12300 21600 26000 33000 43000 54000 70000 Voltage (V) V/Hz 3...
inquiry
detail
2019 Latest Design R134a Heat Pump - 8KW-112KW geothermal heat pump for heating cooling DHW – New Energy
GS series Geothermal source heat pump(heating and cooling or hot water unit) Item NERS- G/2S G/3S G/4S G/5S G/6S G/8S G/10S G/12S G/16S G/20S G/25S G/30S G/40S G/50S Rated heating water capicity (W) W 7400 10800 14300 17700 21100 28100 34000 40800 54300 71300 89200 108700 137000 178000 Input power (W) W 1700 2500 3300 4100 4900 6400 7700 9500 9500 13200 13200 25900 32600 42400 COP 4.35 4.32 4.33 4.32 4.31 4.39 4.42 4.29 5.72 5.40 6.76 4.20 4.20 4.20 Rated cool...
inquiry
detail
China OEM Italy Heat Pump - 8KW-112KW geothermal heat pump for heating cooling DHW – New Energy
GS series Geothermal source heat pump(heating and cooling or hot water unit) Item NERS- G/2S G/3S G/4S G/5S G/6S G/8S G/10S G/12S G/16S G/20S G/25S G/30S G/40S G/50S Rated heating water capicity (W) W 7400 10800 14300 17700 21100 28100 34000 40800 54300 71300 89200 108700 137000 178000 Input power (W) W 1700 2500 3300 4100 4900 6400 7700 9500 9500 13200 13200 25900 32600 42400 COP 4.35 4.32 4.33 4.32 4.31 4.39 4.42 4.29 5.72 5.40 6.76 4.20 4.20 4.20 Rated cool...
inquiry
detail
Manufactur standard Pool Heat Pump Inverter - Air source water heater domestic heat pump pool water heat exchanger 20kw B5Y – New Energy
Specification Model NERS- B/1.5Y B/2Y B/2.5Y B/3Y B/5Y B/6Y G/8Y G/10Y G/12Y G/24Y G/30Y G/40Y Rated heating capicity KW 6.5 9 10.5 12.8 22.5 26.2 34.5 45 53.2 101 120 150 Cooling capicity KW 4.55 6.3 7.35 8.96 15.7 18.3 23.5 30 37.2 74.2 91 106.8 Input power KW 1.2 1.67 1.95 2.43 4.24 5.12 6.65 8.65 10.2 19.6 23.5 29.1 Power source V/Hz 220V-240V 50Hz / 1phase 380V-400V / 50HZ / 3phase Rated output water temperature °C Rated temperature : 26℃~28℃ , Max temperature : 40℃ Wat...
inquiry
detail
<<
< Previous
3
4
5
6
7
8
9
Next >
>>
Page 6 / 13
Phone
Tel
+86 20 86833226
E-mail
E-mail
nulite01@ne01-e.com
Hit enter to search or ESC to close