Split Heat Pump
-
Trending Products Heating Systems - -25c work 19.7kw mono block EVI Air Source Heat Pump water heater model B5S-D – New Energy
GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Microcomputer central pr... -
China OEM Mini Split Heat Pump - -25c work 72kw mono block EVI Air Source Heat Pump water heater model NERS-G20D – New Energy
GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Microcomputer central pr... -
2019 China New Design Domestic Heat Pump - -25c work 140kw mono block EVI Air Source Heat Pump water heater model NERS-G40D – New Energy
Product Information GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Micr... -
Factory Promotional High Quality Heat Pump - -25c work 72kw mono block EVI Air Source Heat Pump water heater model NERS-G20D – New Energy
GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Microcomputer central pr... -
2019 Latest Design Water Heating Pump - 3.65KW 70C high temp. wall temperature all in one heat pump water heater FR1.5F – New Energy
1. Wall mounted type 2. 70C high temperature 3. 70L water tank inside 4. 1.5KW electric heater 5. External microchannel coil can fast heating. Wall mounted all in one heat pump: 1.70~75°C output water temperature and super COP 4.23 2.Using R134A green refrigeration. 3.Energy saving 75%, saving more running cost. 4.Mini size and monoblock type ,zero occupation,easy installation . 5.Strong insulation effect, 24 hours water temperature only drop <3 °C. 6.3 times fast heating technology, ... -
8 Year Exporter Mini Heat Pump - monoblock DC Inverter 20KW BKDX50-200I/1/S A+ Heat Pump Water Heater(Heating & Cooling & Hot Water) – New Energy
NEW ENERGY Minus 25C 10KW 20KW High COP DC Inverter Monoblock Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Heat Pump. HEAT PUMP TYPE DC ... -
OEM manufacturer Commercial Pool/Spa Heat Pump Water Heater - Air source water heater domestic heat pump pool water heat exchanger 20kw B5Y – New Energy
Specification Model NERS- B/1.5Y B/2Y B/2.5Y B/3Y B/5Y B/6Y G/8Y G/10Y G/12Y G/24Y G/30Y G/40Y Rated heating capicity KW 6.5 9 10.5 12.8 22.5 26.2 34.5 45 53.2 101 120 150 Cooling capicity KW 4.55 6.3 7.35 8.96 15.7 18.3 23.5 30 37.2 74.2 91 106.8 Input power KW 1.2 1.67 1.95 2.43 4.24 5.12 6.65 8.65 10.2 19.6 23.5 29.1 Power source V/Hz 220V-240V 50Hz / 1phase 380V-400V / 50HZ / 3phase Rated output water temperature °C Rated temperature : 26℃~28℃ , Max temperature : 40℃ Wat... -
Hot New Products Inverter Heat Pump - monoblock DC Inverter 10KW BKDX30-95I/1/S A+ Heat Pump Water Heater(Heating & Cooling & Hot Water) – New Energy
NEW ENERGY Minus 25C 10KW 20KW High COP DC Inverter Monoblock Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Heat Pump. HEAT PUMP TYPE DC I... -
Factory best selling Water To Air Heat Pump - New Energy Freestanding Fan Coil Unit NERS-380FP – New Energy
New Energy Freestanding Fan Coil Unit NERS-380FP NEW ENERGY Fan Coil Unit & Wireless Pump Controller Instuction 1. NEW ENERGY Heat Pump Fan Coil Units can connect by the wireless and matches with the new energy wireless water pump controller. 2. When all the fan coil units stay on the “off or air purification” mode, wirelss water pump controller will cut off the water pump power, and the water pump will stop running. 3. When the fan coil unit is in the heating mode, then wir... -
Factory source Dc Inverter Swimmng Pool Heat Pump - New Energy 32kw G8Y air source water heater domestic heat pump pool water heat exchanger for villa – New Energy
Specification Model NERS- B/1.5Y B/2Y B/2.5Y B/3Y B/5Y B/6Y G/8Y G/10Y G/12Y G/24Y G/30Y G/40Y Rated heating capicity KW 6.5 9 10.5 12.8 22.5 26.2 34.5 45 53.2 101 120 150 Cooling capicity KW 4.55 6.3 7.35 8.96 15.7 18.3 23.5 30 37.2 74.2 91 106.8 Input power KW 1.2 1.67 1.95 2.43 4.24 5.12 6.65 8.65 10.2 19.6 23.5 29.1 Power source V/Hz 220V-240V 50Hz / 1phase 380V-400V / 50HZ / 3phase Rated output water temperature °C Rated temperature : 26℃~28℃ , Max temperature : 40℃ ... -
Best Price on High Efficiency Heat Pump - Mini air to water spa pool water heater heat pump 6kw B1.5Y – New Energy
Specification Model NERS- B/1.5Y B/2Y B/2.5Y B/3Y B/5Y B/6Y G/8Y G/10Y G/12Y G/24Y G/30Y G/40Y Rated heating capicity KW 6.5 9 10.5 12.8 22.5 26.2 34.5 45 53.2 101 120 150 Cooling capicity KW 4.55 6.3 7.35 8.96 15.7 18.3 23.5 30 37.2 74.2 91 106.8 Input power KW 1.2 1.67 1.95 2.43 4.24 5.12 6.65 8.65 10.2 19.6 23.5 29.1 Power source V/Hz 220V-240V 50Hz / 1phase 380V-400V / 50HZ / 3phase Rated output water temperature °C Rated temperature : 26℃~28℃ , Max temperature : 40℃ Wat... -
2019 High quality 380v Heat Pump - -25c work 72kw mono block EVI Air Source Heat Pump water heater model NERS-G20D – New Energy
GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Microcomputer central pr...