Home
Products
DC Inverter Heat Pump
Monoblock (EVI) Inverter Heat Pump
Split Inverter Heat Pump
All-In-One Heat Pump(Built-in tank)
Commercial Heat Pump
High-temp(℃)Heat Pump
On-off Water Heater Heat Pump
(EVI) Air Conditioning Heat Pump
Swimming Pool Heat Pump
Residential Pool Heater Heat Pump
Commercial Swim Pool Heat Pump
Geothermal/Water Source Heat Pump
Fan Coils
Pressurized Water Tanks
News
Production application
FAQs
About Us
Technology
About HP
Contact Us
English
Home
Tag Archives: Split Heat Pump
Split Heat Pump
Fast delivery Pompe A Chaleur - 125KW EVI heat pump for heating cooling model NERS-G40KD – New Energy
Product Information Specification Item NERS- B/3KD B/5KD G/10KD G/20KD Rated heating capicity KW 9.9 17.5 35 72 Rated cooling capicity KW 7.8 13.7 27.4 56 Rated input power KW 2.35 4.56 9.12 18.5 Max input power KW 3.29 6.5 13.1 27.2 Voltage (V) V/Hz 220v-1phase 380V-3phase Rated output cool water temp °C 8°C~12°C Rated output heating water temp °C 25°C~40°C Refrigeration R407C Control mode Microcomputer central processor (linear contr...
inquiry
detail
Cheap price Bomba De Calor - Good quality hospital 40kw G10K water chiller air conditioner heat pump – New Energy
GK series small Central Air-con/Water Chiller unit Item NERS- G/2K G/3K G/5K G/6K G/10K G/12K G/15K G/20K G/24K Rated heating capicity W 6000 8400 15000 18500 29500 34120 40150 52500 68000 Input power for heating W 1970 2795 4690 5820 9380 11040 13200 17800 22300 Rated cooling capicity W 5580 7480 12800 16310 26170 31040 37600 50200 63800 Input power for cooling W 1890 2560 4400 5600 9010 10580 12800 17100 21900 Voltage V/Hz 220V- 50Hz - 1phase 380V-50Hz-3phases Rated A...
inquiry
detail
Factory selling 240v Heat Pump - 9kw high temperature 80c heat pump NERS-B3S-I – New Energy
1.Compressor: Copelan*ZW series compressor with R134a refrigerant,Running Temp: -10℃~45℃ 2.Internal rotor motor, magnesium aluminum alloy leaves. 3.Reverse preventing frosting function of evaporator, hydrophilic fin. 4.Colored plate, with fashion appearance design. 5.Super performance in high COP, can work under the ambient temperature range from -10 to 43 degree. 6.Intelligent Microcomputer controller,Timer and Clock Function,Timer and Clock Function,Parameters Setting Permissions,L...
inquiry
detail
PriceList for R410a Evi Heat Pump - -25c work 19.7kw mono block EVI Air Source Heat Pump water heater model B5S-D – New Energy
GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Microcomputer central pr...
inquiry
detail
Short Lead Time for Air Source Water Heater - 38kW air to water hot water heat pump for hotel model NERS-G10B – New Energy
GB series commercial heat pump Model NERS- G/3B G/5B G/6B G/8B G/10B G/12B G/20B G/24B G/30B Rated heating capicity KW 11.4KW 19.7KW 23.57KW 30kw 38.5KW 44.7KW 72KW 90.3KW 112KW Input power KW 2.57KW 4.45KW 5.3KW 7.5KW 8.73KW 10.11KW 18KW 20.3KW 27.8KW Voltage V/Hz 380V-50Hz 380V-50Hz 380V/50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz Rated output water temperature °C Rated output water quantity (L) L 240 420 507 645 830 960 1504 1940 2430 Re...
inquiry
detail
Good quality Slovak Heat Pump - 125KW EVI heat pump for heating cooling model NERS-G40KD – New Energy
Product Information Specification Item NERS- B/3KD B/5KD G/10KD G/20KD Rated heating capicity KW 9.9 17.5 35 72 Rated cooling capicity KW 7.8 13.7 27.4 56 Rated input power KW 2.35 4.56 9.12 18.5 Max input power KW 3.29 6.5 13.1 27.2 Voltage (V) V/Hz 220v-1phase 380V-3phase Rated output cool water temp °C 8°C~12°C Rated output heating water temp °C 25°C~40°C Refrigeration R407C Control mode Microcomputer central processor (linear contr...
inquiry
detail
Professional Design Toplinska Pumpa - monoblock DC Inverter 30KW BKDX80-280I/1/S A+ Heat Pump Water Heater(Heating & Cooling & Hot Water) – New Energy
NEW ENERGY Minus 25C 10KW 20KW High COP DC Inverter Monoblock Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Heat Pump. HEAT PUMP TYPE DC ...
inquiry
detail
OEM/ODM Supplier Modular Air Source Heat Pump Hvac System - -25c work 38.5kw mono block EVI Air Source Heat Pump water heater model NERS-G10D – New Energy
GD series EVI low temperature heat pump(-25dC~43dC) Item NERS-B3S-D NERS-B5S-D NERS-G10D NERS-G20D NERS-G40D Rated heating capicity KW 10.4 19.7 38.5 72 140 Input power KW 2.38 4.69 9.38 18.5 35.4 Voltage V/Hz/Ph 380/50/3 380/50/3 380/50/3 380/50/3 380/50/3 Rated current A 11/3.7 8.4 16.8 33.1 63.3 Rated output water temperature °C 55°C Max temp.: 60°C Hot water ouput L/H 250 420 830 1504 3010 Refrigeration R407C Control mode Microcomputer central pr...
inquiry
detail
Factory wholesale Heat Pump Inverter Split - DC Inverter All In One 38KW NE-NC10BZ-B2FIIF Heat Pump Water Heater(Heating & Cooling) – New Energy
NEW ENERGY Minus 25C 10KW 20KW 22KW 30KW 38KW High COP DC Inverter All In One Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter All In One 10KW 20KW 22KW 30KW 38KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Hea...
inquiry
detail
OEM/ODM China Air To Water Heat Pump Inverter - monoblock DC Inverter 30KW BKDX80-280I/1/S A+ Heat Pump Water Heater(Heating & Cooling & Hot Water) – New Energy
NEW ENERGY Minus 25C 10KW 20KW High COP DC Inverter Monoblock Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter Split 10KW 20KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Heat Pump. HEAT PUMP TYPE DC ...
inquiry
detail
Fast delivery Multifunctional Heat Pump Hot Water - 4.2KW Heating Capacity New Energy Freestanding Fan Coil Unit NERS-FP51G – New Energy
Model NERS-FP51G Heating capacity W 4200 Cooling capacity W 3600 House heating area ㎡ 20-40 Power (W) W 30 Voltage (V) V 220V~50Hz Current A 0.09 Water flow L/S 0.08 Nosie level dB(A) 40 Max allowable pressure of heat exchanger MPa 1.6 Weight KG 22 Floor heating floorstanding digital fan coil (Ultra thin) NEW ENERGY customized floor fan coil Thinner ,more save space Product Spec Principle of working Strict quality control Successful projects &...
inquiry
detail
Hot-selling Air Source Heat Pump 20kw Inverter - DC Inverter All In One 20KW NE-C5BZ-B2F Heat Pump Water Heater(Heating & Cooling) – New Energy
NEW ENERGY Minus 25C 10KW 20KW 22KW 30KW 38KW High COP DC Inverter All In One Air to Water Heat Pump. 1.ASHP Heating Capacity: DC Inverter All In One 10KW 20KW 22KW 30KW 38KW. 2.Best Selling Market: Central Europe North & East Europe, North Europe, North America. 3.Ambient Temp of Using: Minus 25C, highest 55-60C hot Water Output. 4.Certification: ISO9001, CE, erP Energy Label, ROHS, EMC. 5.Japan *Mitsubishi” Twin Rotor Compressor for DC Inverter Monoblock Air Source Hea...
inquiry
detail
<<
< Previous
15
16
17
18
19
20
21
Next >
>>
Page 18 / 22
Phone
Tel
+86 20 86833226
E-mail
E-mail
nulite01@ne01-e.com
Hit enter to search or ESC to close