Home
Products
DC Inverter Heat Pump
Monoblock (EVI) Inverter Heat Pump
Split Inverter Heat Pump
All-In-One Heat Pump(Built-in tank)
Commercial Heat Pump
High-temp(℃)Heat Pump
On-off Water Heater Heat Pump
(EVI) Air Conditioning Heat Pump
Swimming Pool Heat Pump
Residential Pool Heater Heat Pump
Commercial Swim Pool Heat Pump
Geothermal/Water Source Heat Pump
Fan Coils
Pressurized Water Tanks
News
Production application
FAQs
About Us
Technology
About HP
Contact Us
English
Home
Tag Archives: Water Heat Pump
Water Heat Pump
Manufactur standard Toplotna Crpalka - NERS-G5Q 16KW Heating Cooling DHW 3 in 1 air to water heat pump – New Energy
Specification Item NERS- G/5Q G/10Q G/12Q G/15Q G/24Q G/30Q G/40Q G/50Q G/60Q G/80Q Rated heating capicity (W) W 16340 35420 41040 48100 82080 96000 135000 173000 215000 283000 Rated cooling capicity (W) W 12500 26720 31480 36200 63990 73000 92000 115000 145000 196000 Input power for heating (W) W 4800 9560 11200 12800 22410 26900 33800 43900 55200 71400 Input power for cooling (W) W 4300 9320 10800 12300 21600 26000 33000 43000 54000 70000 Voltage (V) V/Hz 3...
inquiry
detail
High Quality Scroll Heat Pump - 5.39KW household all in one heat pump for DHW model FDV1.5/Y220 – New Energy
Specification Item NERS- FDV1.5/Y160 FDV1.5/Y220 Rated heating capicity W 5390 5390 Input power W 1275 1275 Voltage V/Hz 220V-50Hz Rated output water temperature °C 55°C Max output water temperature °C 70°C Water tank capacity L 160L 220L Refrigeration R134A Control mode Microcomputer central processor (touch control) Compressor Form Rotation type Quantity 1 1 Brand Mitsubishi UNIT Net size mm 583*339*1782 741*444*1845 Weight Kg 91 115 ...
inquiry
detail
Super Purchasing for Caideal Teasa - CE approved swimming pool heat pump water heater for small pool and spa 12.8kw B3Y – New Energy
Specification Model NERS- B/1.5Y B/2Y B/2.5Y B/3Y B/5Y B/6Y G/8Y G/10Y G/12Y G/24Y G/30Y G/40Y Rated heating capicity KW 6.5 9 10.5 12.8 22.5 26.2 34.5 45 53.2 101 120 150 Cooling capicity KW 4.55 6.3 7.35 8.96 15.7 18.3 23.5 30 37.2 74.2 91 106.8 Input power KW 1.2 1.67 1.95 2.43 4.24 5.12 6.65 8.65 10.2 19.6 23.5 29.1 Power source V/Hz 220V-240V 50Hz / 1phase 380V-400V / 50HZ / 3phase Rated output water temperature °C Rated temperature : 26℃~28℃ , Max temperature : 40℃ Wat...
inquiry
detail
OEM/ODM Manufacturer Warmepumpe - NERS-G24Q 82KW Heating Cooling DHW 3 in 1 air to water heat pump – New Energy
Specification Item NERS- G/5Q G/10Q G/12Q G/15Q G/24Q G/30Q G/40Q G/50Q G/60Q G/80Q Rated heating capicity (W) W 16340 35420 41040 48100 82080 96000 135000 173000 215000 283000 Rated cooling capicity (W) W 12500 26720 31480 36200 63990 73000 92000 115000 145000 196000 Input power for heating (W) W 4800 9560 11200 12800 22410 26900 33800 43900 55200 71400 Input power for cooling (W) W 4300 9320 10800 12300 21600 26000 33000 43000 54000 70000 Voltage (V) V/Hz 3...
inquiry
detail
Factory wholesale Uk Heat Pump - Good quality hospital 40kw G10K water chiller air conditioner heat pump – New Energy
GK series small Central Air-con/Water Chiller unit Item NERS- G/2K G/3K G/5K G/6K G/10K G/12K G/15K G/20K G/24K Rated heating capicity W 6000 8400 15000 18500 29500 34120 40150 52500 68000 Input power for heating W 1970 2795 4690 5820 9380 11040 13200 17800 22300 Rated cooling capicity W 5580 7480 12800 16310 26170 31040 37600 50200 63800 Input power for cooling W 1890 2560 4400 5600 9010 10580 12800 17100 21900 Voltage V/Hz 220V- 50Hz - 1phase 380V-50Hz-3phases Rated A...
inquiry
detail
Top Suppliers Integrated Heat Pump - 4.2KW Heating Capacity Nulite New Energy Freestanding Fan Coil Unit NERS-FP51G – New Energy
Model NERS-FP51G Heating capacity W 4200 Cooling capacity W 3600 House heating area ㎡ 20-40 Power (W) W 30 Voltage (V) V 220V~50Hz Current A 0.09 Water flow L/S 0.08 Nosie level dB(A) 40 Max allowable pressure of heat exchanger MPa 1.6 Weight KG 22 Floor heating floorstanding digital fan coil (Ultra thin) NEW ENERGY customized floor fan coil Thinner ,more save space Product Spec Principle of working Strict quality control Successful projects &am...
inquiry
detail
Manufacturing Companies for Hvac Systems Heat Pump - 5.39KW household all in one heat pump for DHW model FDV1.5/Y220 – New Energy
Specification Item NERS- FDV1.5/Y160 FDV1.5/Y220 Rated heating capicity W 5390 5390 Input power W 1275 1275 Voltage V/Hz 220V-50Hz Rated output water temperature °C 55°C Max output water temperature °C 70°C Water tank capacity L 160L 220L Refrigeration R134A Control mode Microcomputer central processor (touch control) Compressor Form Rotation type Quantity 1 1 Brand Mitsubishi UNIT Net size mm 583*339*1782 741*444*1845 Weight Kg 91 115 ...
inquiry
detail
OEM Factory for Calor Sentinam - 24kw commercial use hot water supply model NERS-G6B – New Energy
GB series commercial heat pump Model NERS- G/3B G/5B G/6B G/8B G/10B G/12B G/20B G/24B G/30B Rated heating capicity KW 11.4KW 19.7KW 23.57KW 30kw 38.5KW 44.7KW 72KW 90.3KW 112KW Input power KW 2.57KW 4.45KW 5.3KW 7.5KW 8.73KW 10.11KW 18KW 20.3KW 27.8KW Voltage V/Hz 380V-50Hz 380V-50Hz 380V/50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz Rated output water temperature °C Rated output water quantity (L) L 240 420 507 645 830 960 1504 1940 24...
inquiry
detail
Factory Free sample Sanitary Hot Water Heat Pump - New Energy 32kw G8Y air source water heater domestic heat pump pool water heat exchanger for villa – New Energy
Specification Model NERS- B/1.5Y B/2Y B/2.5Y B/3Y B/5Y B/6Y G/8Y G/10Y G/12Y G/24Y G/30Y G/40Y Rated heating capicity KW 6.5 9 10.5 12.8 22.5 26.2 34.5 45 53.2 101 120 150 Cooling capicity KW 4.55 6.3 7.35 8.96 15.7 18.3 23.5 30 37.2 74.2 91 106.8 Input power KW 1.2 1.67 1.95 2.43 4.24 5.12 6.65 8.65 10.2 19.6 23.5 29.1 Power source V/Hz 220V-240V 50Hz / 1phase 380V-400V / 50HZ / 3phase Rated output water temperature °C Rated temperature : 26℃~28℃ , Max temperature : 40℃ ...
inquiry
detail
Bottom price Sanitary Split Type Heat Pump - 35KW EVI heat pump for heating cooling model NERS-G10KD – New Energy
duct Information Specification Item NERS- B/3KD B/5KD G/10KD G/20KD Rated heating capicity KW 9.9 17.5 35 72 Rated cooling capicity KW 7.8 13.7 27.4 56 Rated input power KW 2.35 4.56 9.12 18.5 Max input power KW 3.29 6.5 13.1 27.2 Voltage (V) V/Hz 220v-1phase 380V-3phase Rated output cool water temp °C 8°C~12°C Rated output heating water temp °C 25°C~40°C Refrigeration R407C Control mode Microcomputer central processor (linear control) Compr...
inquiry
detail
Manufacturer for Modular Air Source Heat Pump Hvac System - 45kw commercial use hot water supply model NERS-G12B – New Energy
GB series commercial heat pump Model NERS- G/3B G/5B G/6B G/8B G/10B G/12B G/20B G/24B G/30B Rated heating capicity KW 11.4KW 19.7KW 23.57KW 30kw 38.5KW 44.7KW 72KW 90.3KW 112KW Input power KW 2.57KW 4.45KW 5.3KW 7.5KW 8.73KW 10.11KW 18KW 20.3KW 27.8KW Voltage V/Hz 380V-50Hz 380V-50Hz 380V/50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz Rated output water temperature °C Rated output water quantity (L) L 240 420 507 645 830 960 1504 1940 24...
inquiry
detail
Cheapest Factory Commercial Heat Pump - 45kw commercial use hot water supply model NERS-G12B – New Energy
GB series commercial heat pump Model NERS- G/3B G/5B G/6B G/8B G/10B G/12B G/20B G/24B G/30B Rated heating capicity KW 11.4KW 19.7KW 23.57KW 30kw 38.5KW 44.7KW 72KW 90.3KW 112KW Input power KW 2.57KW 4.45KW 5.3KW 7.5KW 8.73KW 10.11KW 18KW 20.3KW 27.8KW Voltage V/Hz 380V-50Hz 380V-50Hz 380V/50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz 380V-50Hz Rated output water temperature °C Rated output water quantity (L) L 240 420 507 645 830 960 1504 1940 24...
inquiry
detail
<<
< Previous
1
2
3
4
5
6
Next >
>>
Page 2 / 15
Phone
Tel
+86 20 86833226
E-mail
E-mail
nulite01@ne01-e.com
Hit enter to search or ESC to close